| Item Name | |
| Part Number/Trade Name | VV-P-236A,PETROLATUM TECHNICAL |
| National Stock Number | 9150002500926 |
| CAGE Code | 4S446 |
| Part Number Indicator | A |
| MSDS Number | 101179 |
| HAZ Code | A |
| Manufacturer Name | UNI-KEM INTERNATIONAL CORPORATION |
| P.O. Box | N/K |
| Street | 513 HICKORY AVENUE |
| City | HARAHAN |
| State | LA |
| Country | US |
| Zip Code | 70123 |
| Emergency Phone | 504-738-1623 |
| Information Phone | 504-738-1623 |
| MSDS Preparer Name | N/K |
| Date MSDS Prepared/Revised | 06JUN90 |
| Date of Technical Review | 20APR91 |
| Active Indicator | Y |
| Item Manager | CX |
| Vendor #5 CAGE | BHYNL |
| Specification Number | VV-P-236, REV A |
| Specification Type/Grade/Class | CLASS 2, TYPE V |
| Hazard Storage Compatibility Code | N1-F6 |
| NRC License Number | N/R |
| Net Propellant Weight (Ammo) | N/R |
| Appearance/Odor | YELLOW OR BROWN,SEMI-SOLID,OIL LIKE,OPAQUE |
| Boiling Point | N/K |
| Melting Point | N/K |
| Vapor Pressure | N/K |
| Vapor Density | N/K |
| Specific Gravity | 0.815 |
| Decomposition Temperature | UNKNOWN |
| Evaporation Rate | N/K |
| Solubility in Water | NEGLIGIBLE |
| Percent Volatiles by Volume | N/K |
| Chemical pH | N/K |
| Corrosion Rate | UNKNOWN |
| Container Pressure Code | 4 |
| Temperature Code | 8 |
| Product State Code | U |
| Flash Point | 400 |
| Flash Point Method | COC |
| Lower Explosion Limit | N/K |
| Upper Explosion Limit | N/K |
| Extinguishing Media | USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY CHEMICAL, SAND OR EARTH |
| Special Fire Fighting Procedures | FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA & FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER SPRAY TO CO NEARBY CONTAINERS EXPOSED TO FIRE |
| Unusual Fire/Explosion Hazards | NONE NOTED;FIRE OR EXCESSIVE HEAT MAY CAUSE PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS |
| Stability | YES |
| Stability Conditions to Avoid | HIGH TEMPERATURES |
| Materials to Avoid | NONE REPORTED |
| Hazardous Decomposition Products | INCOMPLETE COMBUSTION WILL EVOLVE OXIDES OF CARBON, NITROGEN AND SULFUR.SMOKE AND SOOT |
| Hazardous Polymerization | NO |
| Polymerization Conditions to Avoid | NOT APPLICABLE |
| LD50 - LD50 Mixture | UNKNOWN |
| Route of Entry: Skin | YES |
| Route of Entry: Ingestion | YES |
| Route of Entry: Inhalation | NO |
| Health Hazards - Acute and Chronic | ACUTE: NO DATA PER MSDS; MAY CAUSE IRRITATION OF EYES, SKIN, RESPIRATORY OR G.I. TRACT OF IF INHALED IN THE FORM OF VAPORS OR MIST |
| Carcinogenity: NTP | NO |
| Carcinogenity: IARC | NO |
| Carcinogenity: OSHA | NO |
| Explanation of Carcinogenity | NOT APPLICABLE |
| Symptoms of Overexposure | INHALATION:OVEREXPOSURE MAY LEAD TO RESPIRATORY IRRITATION. INGESTION:MAY CAUSE NAUSEA,VOMITING,AND DIARRHEA AND POSSIBLY UNCONSCIOUSNESS. EYES:CAUSES MILD IRRITATION ON CONTACT.VAPORS MAY CAUSE TEARS/IRRITATION. SKIN:COMPONENTS ARE UNLIKELY TO BE ABSORBED THROUGH SKIN IN HARMFUL CONCENTRATION BUT MAY CAUSE IRRITATION |
| Medical Cond. Aggrevated by Exposure | NONE SPECIFIED BY MANUFACTURER |
| Emergency/First Aid Procedures | EYES AND SKIN: FLUSH WITH LARGE AMOUNT OF WATER FOR ABOUT 15-20 MINUTES; SEEK MEDICAL ATTENTION IMMEDIATELY. INHALATION: REMOVE TO FRESH AIR; CALL A PHYSICIAN. INGESTION: SEEK MEDICAL ATTENTION IMMEDIATELY |
| Steps if Material Released/Spilled | USE PROPER PERSONAL PROTECTION; SCRAP AND COLLECT FOR PROPER DISPOSAL IN AN APPROVED CONTAINER. DIKE BULK SPILL WITH INERT ABSORBENT TO PREVENT FROM ENTERING THE WATERWAYS |
| Neutralizing Agent | N/R |
| Waste Disposal Method | CONSULT LOCAL AUTHORITIES;DISPOSAL MUST BE IN ACCORDANCE WITH LOCAL,STATE AND FEDERAL REGULATIONS |
| Handling and Storage Precautions | RE IN COOL,DRY AND WELL VENTILATED AREA.KEEP CONTAINER CLOSED WHEN NOT IN USE. TH |
| Other Precautions | THE SELECTION OF PERSONAL PROTECTIVE EQUIPMENT SHOULD BE MADE BY THE MATERIAL USER BASED ON THE PARTICULAR CONDITIONS WHERE THE MATERIAL IS TO BE USED TOGETHER WITH INFORMATION CONTAINED IN THIS MSDS.GROUND/BOND ALL EQUIPMENT WHEN TRANSFERG |
| Respiratory Protection | NORMALLY NOT REQUIRED;USE NIOSH/MSHA APPROVED RESPIRATOR FOR DUST/MIST IF ABOVE PEL/TLV |
| Ventilation | NORMAL ROOM VENTILATION |
| Protective Gloves | IMPERVIOUS |
| Eye Protection | SAFETY GLASSES/GOGGLES |
| Other Protective Equipment | PROTECTIVE CLOTHES. EYE-WASH FACILITIES, SAFETY SHOWER |
| Work Hygenic Practices | AVOID CONTACT WITH EYES AND SKIN;DO NOT BREATHE VAPORS/MIST/DUST.WASH THOROUGHLY AFTER EACH USE;DO NOT EAT,DRINK,SMOKE |
| Supplemental Health/Safety Data | READ ALL LABELS CAREFULLY BEFORE USING |
| Disposal Code | N |
| Protect Eye | YES |
| Protect Skin | YES |
| Protect Respiratory | YES |
| Chronic Indicator | YES |
| Contact Code | SLIGHT |
| Fire Code | UNKNOWN |
| Health Code | UNKNOWN |
| React Code | UNKNOWN |
| Container Quantity | 1.75 |
| Unit of Measure | LB |
| Volatile Organic Compounds (P/G) | 0 |
| Volatile Organic Compounds (G/L) | 0 |
| Ingredient # | 01 |
| Ingredient Name | PETROLATUM |
| CAS Number | 8009038 |
| NIOSH Number | 1001480PG |
| Proprietary | NO |
| Percent | 0 |
| OSHA PEL | 5 MG/M3 AS OIL MIST |
| ACGIH TLV | 5 MG/M3 AS OIL MIST |
| Recommended Limit | NONE SPECIFIED |