Material Safety Data Sheet


SECTION I - Material Identity
SECTION II - Manufacturer's Information
SECTION III - Physical/Chemical Characteristics
SECTION IV - Fire and Explosion Hazard Data
SECTION V - Reactivity Data
SECTION VI - Health Hazard Data
SECTION VII - Precautions for Safe Handling and Use
SECTION VIII - Control Measures
SECTION IX - Label Data
SECTION X - Transportation Data
SECTION XI - Site Specific/Reporting Information
SECTION XII - Ingredients/Identity Information



SECTION I - Material Identity
Item Name                               
Part Number/Trade Name                   REFRIGERANT 12, FREON 12, GENETRON 12, (SUP
National Stock Number                    6830013446534
CAGE Code                                2A580
Part Number Indicator                    A
MSDS Number                              147008
HAZ Code                                 M


SECTION II - Manufacturer's Information
Manufacturer Name                        RACON INC
P.O. Box                                 198
City                                     WICHITA
State                                    KS
Country                                  US
Zip Code                                 67201
Emergency Phone                          415-821-5338
Information Phone                        316-524-3245 OR 800-835-2916

MSDS Preparer's Information
Date MSDS Prepared/Revised               07APR89
Date of Technical Review                 19MAY92
Active Indicator                         N

Alternate Vendors
Vendor #5 CAGE                           BNRMF


SECTION III - Physical/Chemical Characteristics
Hazard Storage Compatibility Code        N-K
Appearance/Odor                          COLORLESS LIQUID & VAPOR WITH VERY SLIGHT ETHEREAL ODOR/ODORLESS 
Boiling Point                            -22F,-30C
Melting Point                            N/K
Vapor Pressure                           SEE ING
Vapor Density                            SEE ING
Specific Gravity                         1.31 (WATER =1)
Decomposition Temperature                N/K
Evaporation Rate                         NOT APPLICABLE
Solubility in Water                      INSOLUBLE
Percent Volatiles by Volume              100
Chemical pH                              N/K
Corrosion Rate                           N/K
Container Pressure Code                  4
Temperature Code                         8
Product State Code                       U


SECTION IV - Fire and Explosion Hazard Data
Flash Point Method                       UNK
Lower Explosion Limit                    N/K
Upper Explosion Limit                    N/K
Extinguishing Media                      MEDIA SUITABLE FOR SURROUNDING FIRE (FP N)
Special Fire Fighting Procedures         WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA AND FULL PROTECTIVE EQUIPMENT (FP N) 
Unusual Fire/Explosion Hazards           THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE CHLORIDES, FLUORIDES AND PHOSGENE (FP N) 


SECTION V - Reactivity Data
Stability                                YES
Stability Conditions to Avoid            AVOID CONDITIONS WHERE CFC-12 MAY CONTACT OPEN FLAMES OR EXTREMELY HOT METAL SURFACES 
Materials to Avoid                       CERTAIN ELASTOMERS, ALKALI/ALKALINE EARTH METALS, POWDERED ALUMINUM, ZINC, BERYLLIUM ETC. MCA REPORTED THAT (SUPDAT)
Hazardous Decomposition Products         CHLORIDES, FLUORIDES & PHOSGENE (FP N). HF, HCL & TRACES OF CARBONYL HALIDES 
Hazardous Polymerization                 NO
Polymerization Conditions to Avoid       NOT RELEVANT
LD50 - LD50 Mixture                      NONE SPECIFIED BY MANUFACTURER 


SECTION VI - Health Hazard Data
Route of Entry: Skin                     NO
Route of Entry: Ingestion                NO
Route of Entry: Inhalation               YES
Health Hazards - Acute and Chronic       CHLOROFLUOROCARBON MATLS HAVE PRODUCED SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMETICS (E.G., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO CFCS (FP N). ACUTE:INHAL:MAY AFFECT RESP/ (EFTS OF OVEREXP)
Carcinogenity: NTP                       NO
Carcinogenity: IARC                      NO
Carcinogenity: OSHA                      NO
Explanation of Carcinogenity             NOT RELEVANT
Symptoms of Overexposure                 HLTH HAZ:CARDIOVASCULAR SYS. MAY CAUSE TINGLING SENSATION, HUMMING IN EARS, APPREHENSION & SLURRED SPEECH, DECREASE IN CONSCIOUSNESS W/AMNESIA, IRREGULAR HEART BEAT, EYE IRRIT, CNS EFTS. SNIFFING OF FLUOROCARBON PROPELLANTS FOR THEIR INTOX EFTS HAS PRODUCED OVER 100 DEATHS. FLUOROCARBONS EXHIBIT VERY TOX (ING 2)
Medical Cond. Aggrevated by Exposure     INDIVIDUALS W/HEART OR RESPIRATORY DISORDERS MAY BE ESPECIALLY SUSCEPTIBLE TO HEALTH HAZARDS 
Emergency/First Aid Procedures           INHAL:REMOVE TO FRESH AIR. KEEP WARM & AT REST. IF BRTHG IS DFCLT (LABORED), GIVE O*2. IF NOT BRTHG, GIVE ARTIF RESP & CHECK FOR PULSE. IF NO PULSE START CPR. DO NOT GIVE STIMULANTS (ADRENALINE, EPINEPHRINE/HAND HELD ASTHMA AEROSOLS). CALL 911 (IF AVAILABLE) & MD. KEEP PATIENT AT REST FOR 24 HRS AFTER OVEREXPOS. NO LONG TERM EFTS ARE EXPECTED. EYE/SKIN:VAP:FLUSH WITH WATER FOR AT LEAST (ING 9)


SECTION VII - Precautions for Safe Handling and Use
Steps if Material Released/Spilled       KEEP UPWIND. VENTILATE ENCLOSED SPACES UNTIL GAS IS DISPERSED. DO NOT SMOKE OR OPERATE INTERNAL COMBUSTION ENGINES IN IMMED VICINITY 
Neutralizing Agent                       NONE SPECIFIED BY MANUFACTURER 
Waste Disposal Method                    DISPOSAL MUST BE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS (FP N). EPA HAZ WASTE# UO75. WHEN REMOVED FROM REFRIDGERATION SYSTEM, MAY BE HAZARDOUS WASTE. CONSULT 40 CFR 261, 262 
Handling and Storage Precautions         NOT BRTH VAP. AVOID CONT W/EYES, SKIN & CLTHG. STORE IN COOL PLACE (<120F). STORE & USE W/ADEQ VENT. LIQUIFIED, COMPRESSED GAS. NO
Other Precautions                        NOT FOR FOOD/DRUG/COSMETIC USE. NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL VICINITY OF ARC WELDING, OPEN FLAMES/HOT SURFACES. HEAT AND/OR UV RADIA MAY CAUSE FORMATION OF CHLORIDES, FLUORIDES AND/OR PHOSGENE (FP N) 


SECTION VIII - Control Measures
Respiratory Protection                   RESP PROT IS NOT NEEDED IF CONC ARE CONTROLLED. IF CON EXCEED TLV (1000 PPM) USE A NIOSH/MSHA APPRVD RESP FOR ORGANIC VAP. IN VERY HIGH CONC, SCBA SHOULD BE USED 
Ventilation                              LOCAL EXHAUST MAY BE NECESSARY TO REDUCE CONC BELOW TLV (1000 PPM) 
Protective Gloves                        CLOTH-LINED RUBBER GLOVES 
Eye Protection                           CHEMICAL WORKERS GOGGLES (FP N) 
Other Protective Equipment               PROTECTIVE CLOTHING SHOULD MIN EXPOSED SKIN & INCLUDE FULL FACE SHIELD IF SPLASHING IS POSSIBLE 
Work Hygenic Practices                   NONE SPECIFIED BY MANUFACTURER 
Supplemental Health/Safety Data          MFR'S TRADE NAME/PART NO:FLUOROCARBON 12, CFC-12, R-12. MATL TO AVOID:ALKALI & ALKALINE EARTH METALS (I E SODIUM, POTASSIUM & BARIUM) IN THEIR FREE METALLIC FORM MAY REACT VIOLENTLY W/FLUOROCARBONS. MATLS BECOME MORE REACTIVE WHEN FINELY GROUND. METALS SUCH AS MN & AL IN POWDER FORM MAY ALSO REACT, ESP AT HIGH TEMP 
Disposal Code                            O


SECTION IX - Label Data
Protect Eye                              YES
Protect Skin                             YES
Protect Respiratory                      YES
Chronic Indicator                        UNKNOWN
Contact Code                             MODERATE
Fire Code                                UNKNOWN
Health Code                              UNKNOWN
React Code                               UNKNOWN


SECTION X - Transportation Data
Container Quantity                       50
Unit of Measure                          LB


SECTION XI - Site Specific/Reporting Information
Volatile Organic Compounds (P/G)         0
Volatile Organic Compounds (G/L)         0


SECTION XII - Ingredients/Identity Information
Ingredient #                             01
Ingredient Name                          METHANE, DICHLORODIFLUORO-; (DICHLORODIFLUOROMETHANE)
CAS Number                               75718
NIOSH Number                             PA8200000
Proprietary                              NO
Percent                                  100
OSHA PEL                                 NOT APPLICABLE
ACGIH TLV                                1000PPM;1250STEL(MFR
Recommended Limit                        N/K