|
||||||
|---|---|---|---|---|---|---|
| Home | 29 CFR | 40 CFR | 49 CFR | Federal Register | MSDS Search | Purchase CFR e-Books |
§796.1950 Vapor pressure.
(a) Introduction -- (1) Background and purpose. (i) Volatilization, the evaporative loss of a chemical, depends upon the vapor pressure of chemical and on environmental conditions which influence diffusion from a surface. Volatilization is an important source of material for airborne transport and may lead to the distribution of a chemical over wide areas and into bodies of water far from the site of release. Vapor pressure values provide indications of the tendency of pure substances to vaporize in an unperturbed situation, and thus provide a method for ranking the relative volatilities of chemicals. Vapor pressure data combined with water solubility data permit the calculation of Henry's law constant, a parameter essential to the calculation of volatility from water.
(ii) Chemicals with relatively low vapor pressures, high adsorptivity onto solids, or high solubility in water are less likely to vaporize and become airborne than chemicals with high vapor pressures or with low water solubility or low adsorptivity to solids and sediments. In addition, chemicals that are likely to be gases at ambient temperatures and which have low water solubility and low adsorptive tendencies are less likely to transport and persist in soils and water. Such chemicals are less likely to biodegrade or hydrolyze and are prime candidates for atmospheric oxidation and photolysis (e.g., smog formation or stratospheric alterations). On the other hand, nonvolatile chemicals are less frequently involved in atmosphere transport, so that concerns regarding them should focus on soils and water.
(iii) Vapor pressure data are an important consideration in the design of other chemical fate and effects tests; for example, in preventing or accounting for the loss of violatile chemicals during the course of the test.
(2) Definitions and units. (i) "Desorption efficiency" of a particular compound applied to a sorbent and subsequently extracted with a solvent is the weight of the compound which can be recovered from the sorbent divided by the weight of the compound originally sorbed.
(ii) "Pascal" (Pa) is the standard international unit of vapor pressure and is defined as newtons per square meter (N/m2). A newton is the force necessary to give acceleration of one meter per second squared to one kilogram of mass.
(iii) The "torr" is a unit of pressure which equals 133.3 pascals or 1 mm Hg at 0 °C.
(iv) "Vapor pressure" is the pressure at which a liquid or solid is in equilibrium with its vapor at a given temperature.
(v) "Volatilization" is the loss of a substance to the air from a surface or from solution by evaporation.
(3) Principle of the test methods. (i) The isoteniscope procedure uses a standardized technique [ASTM 1978] that was developed to measure the vapor pressure of certain liquid hydrocarbons. The sample is purified within the equipment by removing dissolved and entrained gases until the measured vapor pressure is constant, a process called "degassing." Impurities more volatile than the sample will tend to increase the observed vapor pressure and thus must be minimized or removed. Results are subject to only slight error for samples containing nonvolatile impurities.
(ii) Gas saturation (or transpiration) procedures use a current of inert gas
passed through or over the test material slowly enough to ensure saturation and
subsequent analysis of either the loss of material or the amount (and sometimes
kind) of vapor generated. Gas saturation procedures have been described by
Spencer and Cliath (1969) under paragraph (d)(2) of this section. Results are
easy to obtain and can be quite precise. The same procedures also can be used to
study volatilization from laboratory scale environmental simulations. Vapor
pressure is computed on the assumption that the total pressure of a mixture of
gases is equal to the sum of the pressures of the separate or component gases
and that the ideal gas law is obeyed. The partial pressure of the vapor under
study can be calculated from the total gas volume and the weight of the material
vaporized. If v is the volume which contains w grams of the vaporized material
having a molecular weight M, and if p is the pressure of the vapor in
equilibrium at temperature T (K), then the vapor pressure, p, of the sample is
calculated by p=(w/M)(RT/v), where R is the gas constant (8.31 Pa m2 mol−1
K−1) when the pressure is in pascals (Pa) and the volume is in cubic
meters. As noted by Spencer and Cliath (1970) under paragraph (d)(3) of this
section, direct vapor pressure measurements by gas saturation techniques are
more directly related to the volatilization of chemicals than are other
techniques.
(iii) In an effort to improve upon the procedure described by Spencer and
Cliath (1969) under paragraph (d)(2) of this section, and to determine the
applicability of the gas saturation method to a wide variety of chemical types
and structures, EPA has sponsored research and development work at SRI
International (EPA 1982) under paragraph (d)(1) of this section. The procedures
described in this Test Guideline are those developed under that contract and
have been evaluated with a wide variety of chemicals of differing structure and
vapor pressures.
(4) Applicability and specificity. (i) A procedure for measuring the
vapor pressure of materials released to the environment ideally would cover a
wide range of vapor pressure values, at ambient temperatures. No single
procedure can cover this range, so two different procedures are described in
this section, each suited for a different part of the range. The isoteniscope
procedure is for pure liquids with vapor pressures from 0.1 to 100 kPa. For
vapor pressures of 10−5 to 103 Pa, a gas saturation
procedure is to be used.
(ii) With respect to the isoteniscope method, if compounds that boil close to
or form azeotropes with the test material are present, it is necessary to remove
the interfering compounds and use pure test material. Impurities more volatile
than the sample will tend to increase the observed vapor pressure above its true
value but the purification steps will tend to remove these impurities. Soluble,
nonvolatile impurities will decrease the apparent vapor pressure. However,
because the isoteniscope procedure is a static, fixed-volume method in which an
insignificant fraction of the liquid sample is vaporized, it is subject to only
slight error for samples containing nonvolatile impurities. That is, the
nonvolatile impurities will not be concentrated due to vaporization of the
sample.
(iii) The gas saturation method is applicable to solid or liquid chemicals.
Since the vapor pressure measurements are made at ambient temperatures, the need
to extrapolate data from high temperatures is not necessary and high temperature
extrapolation, which can often cause serious errors, is avoided. The method is
most reliable for vapor pressures below 103 Pa. Above this limit, the
vapor pressures are generally overestimated, probably due to aerosol formation.
Finally, the gas saturation method is applicable to the determination of the
vapor pressure of impure materials.
(b) Test procedures -- (1) Test conditions. (i) The apparatus
in the isoteniscope method is described in paragraph (b)(2)(i) of this section.
(ii) The apparatus used in the gas saturation method is described in
paragraph (b)(2)(ii) of this section.
(2) Performance of the tests -- (i) Isoteniscope Procedure. The
isoteniscope procedure described as ANSI/ASTM Method D 2879-86 is applicable for
the measurement of vapor pressures of liquids with vapor pressures of 0.1 to 100
kilopascals (kPa) (0.75 to 750 torr). ASTM D 2879-86 is available for inspection
at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700,
Washington, DC. This incorporation by reference was approved by the Director of
the Office of the Federal Register. This material is incorporated as it exists
on the date of approval and a notice of any change in this material will be
published in the FEDERAL REGISTER. Copies of the incorporated material may be
obtained from the Non-Confidential Information Center (NCIC) (7407), Office of
Pollution Prevention and Toxics, U.S. Environmental Protection Agency, Room
B-607 NEM, 401 M St., SW., Washington, DC 20460, between the hours of 12 p.m.
and 4 p.m. weekdays excluding legal holidays, or from the American Society for
Testing and Materials (ASTM), 1916 Race Street, Philadelphia, PA 19103. The
isoteniscope method involves placing liquid sample in a thermostated bulb (the
isoteniscope) connected to a manometer and a vacuum pump. Dissolved and
entrained gases are removed from the sample in the isoteniscope by degassing the
sample at reduced presssure. The vapor pressure of the sample at selected
temperatures is determined by balancing the pressure due to the vapor of the
sample against a known pressure of an inert gas. The vapor pressure of the test
compound is determined in triplicate at 25±0.5 °C and at any other suitable
temperatures (±0.5°). It is important that additional vapor pressure
measurements be made at other temperatures, as necessary, to assure that there
is no need for further degassing, as described in the ASTM method.
(ii) Gas saturation procedure. (A) The test procedures require the use
of a constant-temperature box as depicted in the following Figure 1.
The insulated box, containing sample holders, may be of any suitable size and
shape. The sketch in Figure 1 shows a box containing three solid sample holders
and three liquid sample holders, which allows for the triplicate analysis of
either a solid or liquid sample. The temperature within the box is controlled to
±0.5° or better. Nitrogen gas, split into six streams and controlled by fine
needle valves (approximately 0.79 mm orifice), flows into the box via 3.8 mm
(0.125 in.) i.d. copper tubing. After temperature equilibration, the gas flows
through the sample and the sorbent trap and exits from the box. The flow rate of
the effluent carrier gas is measured at room temperature with a bubble flow
meter or other suitable device. The flow rate is checked frequently during the
experiment to assure that there is an accurate value for the total volume of
carrier gas. The flow rate is used to calculate the total volume (at room
temperature) of gas that has passed through the sample and sorbent [(vol/time) ×
time = volume]. The vapor pressure of the test substance can be calculated from
the total gas volume and the mass of sample vaporized. If v is the volume of gas
that transported mass w of the vaporized test material having a molecular weight
M, and if p is the equilibrium vapor pressure of the sample at temperature T,
then p is calculated by the equation p=(w/M)(RT/v). In this equation, R is the gas constant (8.31 Pa m
3mol−1 K−1). The pressure is expressed in
pascals (Pa), the volume in cubic meters (m 3), mass in grams and T
in kelvins (K). T=273.15+t, if t is measured in degrees Celsius (°C).
(B) Solid samples are loaded into 5 mm i.d. glass tubing between glass wool
plugs. The following Figure 2 depicts a drawing of a sample holder and absorber
system.
(C) Liquid samples are contained in a holder as shown in the following Figure
3.
The most reproducible method for measuring the vapor pressure of liquids is
to coat the liquid on glass beads and to pack the holder in the designated place
with these beads.
(D) At very low vapor pressures and sorbent loadings, adsorption of the
chemical on the glass wool separating the sample and the sorbent and on the
glass surfaces may be a serious problem. Therefore, very low loadings should be
avoided whenever possible. Incoming nitrogen gas (containing no interfering
impurities) passes through a coarse frit and bubbles through a 38 cm column of
liquid sample. The stream passes through a glass wool column to trap aerosols
and then through a sorbent tube, as described above. The pressure drop across
the glass wool column and the sorbent tube are negligible.
(E) With both solid and liquid samples, at the end of the sampling time, the
front and backup sorbent sections are analyzed separately. The compound on each
section is desorbed by adding the sorbent from that section to 1.0 ml of
desorption solvent in a small vial and allowing the mixture to stand at a
suitable temperature until no more test compound desorbs. It is extremely
important that the desorption solvent contain no impurities which would
interfere with the analytical method of choice. The resulting solutions are
analyzed quantitatively by a suitable analytical method to determine the weight
of sample desorbed from each section. The choice of the analytical method,
sorbent, and desorption solvent is dictated by the nature of the test material.
Commonly used sorbents include charcoal, Tenax GC, and XAD-2. Describe in detail
the sorbent, desorption solvent, and analytical methods employed.
(F) Measure the desorption efficiency for every combination of sample,
sorbent, and solvent used. The desorption efficiency is determined by injecting
a known mass of sample onto a sorbent and later desorbing it and analyzing for
the mass recovered. For each combination of sample, sorbent, and solvent used,
carry out the determination in triplicate at each of three concentrations.
Desorption efficiency may vary with the concentration of the actual sample and
it is important to measure the efficiency at or near the concentration of sample
under gas saturation test procedure conditions.
(G) To assure that the gas is indeed saturated with test compound vapor,
sample each compound at three differing gas flow rates. Appropriate flow rates
will depend on the test compound and test temperature. If the calculated vapor
pressure shows no dependence on flow rate, then the gas is assumed to be
saturated.
(c) Data and reporting. (1) Report the triplicate calculated vapor
pressures for the test material at each temperature, the average calculated
vapor pressure at each temperature, and the standard deviation.
(2) Provide a description of analytical methods used to analyze for the test
material and all analytical results.
(3) For the isoteniscope procedure, include the plot of p vs. the reciprocal
of the temperature in K, developed during the degasing step and showing
linearity in the region of 298.15 K (25°C) and any other required
test temperatures.
(4) For the gas saturation procedure, include the data on the calculation of
vapor pressure at three or more gas flow rates at each test temperature, showing
no dependence on flow rate. Include a description of sorbents and solvents
employed and the desorption efficiency calculations.
(5) Provide a description of any difficulties experienced or any other
pertinent information.
(d) References. For additional background information on this test
guideline the following references should be consulted:
(1) U.S. Environmental Protection Agency. Evaluation of Gas Saturation
Methods to Measure Vapor Pressures: Final Report, EPA Contract No.
68-01-5117 with SRI International, Menlo Park, California (1982).
(2) Spencer, W.F. and Cliath, M.M. "Vapor Density of Dieldrin," Journal of
Agricultural and Food Chemistry, 3:664-670 (1969).
(3) Spencer, W.F. and Cliath, M.M. "Vapor Density and Apparent Vapor Pressure
of Lindane," Journal of Agricultural and Food Chemistry, 18:529-530
(1970).
[50 FR 39252, Sept. 27, 1985, as amended at 53 FR 12525, Apr. 15,
1988; 53 FR 21641, June 9, 1988; 60 FR 34466, July 3,
1995]