Title 29 -- Labor

Home 29 CFR:  1910 1926 40 CFR 49 CFR Federal  Register MSDS Search Purchase CFR e-Books

 

Previous Home Next


 

§1926.56 Illumination.


(a) General. Construction areas, ramps, runways, corridors, offices, shops, and storage areas shall be lighted to not less than the minimum illumination intensities listed in Table D-3 while any work is in progress:

       Table D-3_Minimum Illumination Intensities in Foot-Candles
------------------------------------------------------------------------
              Foot-candles                      Area or operation
------------------------------------------------------------------------
5......................................  General construction area
                                          lighting.
3......................................  General construction areas,
                                          concrete placement, excavation
                                          and waste areas, accessways,
                                          active storage areas, loading
                                          platforms, refueling, and
                                          field maintenance areas.
5......................................  Indoors: warehouses, corridors,
                                          hallways, and exitways.
5......................................  Tunnels, shafts, and general
                                          underground work areas:
                                          (Exception: minimum of 10 foot-
                                          candles is required at tunnel
                                          and shaft heading during
                                          drilling, mucking, and
                                          scaling. Bureau of Mines
                                          approved cap lights shall be
                                          acceptable for use in the
                                          tunnel heading.)
10.....................................  General construction plant and
                                          shops (e.g., batch plants,
                                          screening plants, mechanical
                                          and electrical equipment
                                          rooms, carpenter shops,
                                          rigging lofts and active
                                          storerooms, barracks or living
                                          quarters, locker or dressing
                                          rooms, mess halls, and indoor
                                          toilets and workrooms).
30.....................................  First aid stations,
                                          infirmaries, and offices.
------------------------------------------------------------------------

(b) Other areas. For areas or operations not covered above, refer to the American National Standard A11.1-1965, R1970, Practice for Industrial Lighting, for recommended values of illumination.


Previous Home Next