| Item Name | |
| Part Number/Trade Name | SOLDERING FLUID GF 5117 |
| National Stock Number | 3439000098808 |
| CAGE Code | 84311 |
| Part Number Indicator | A |
| MSDS Number | 182226 |
| HAZ Code | B |
| Manufacturer Name | GARDINER SOLDER CO |
| Street | 4820 SO CAMPBELL AVE |
| City | CHICAGO |
| State | IL |
| Country | US |
| Zip Code | 60632 |
| Information Phone | 312-847-0100 |
| Date MSDS Prepared/Revised | 13FEB87 |
| Active Indicator | N |
| Vendor #1 CAGE | 84311 |
| Appearance/Odor | CLEAR LIMPID; VERY FAINT ODOR |
| Boiling Point | 212F; 100C |
| Vapor Pressure | <1 |
| Specific Gravity | 1.0 |
| Evaporation Rate | NONE |
| Solubility in Water | COMPLETE |
| Percent Volatiles by Volume | 83% |
| Chemical pH | 5-1.9% |
| Container Pressure Code | 4 |
| Temperature Code | 8 |
| Product State Code | L |
| Flash Point Method | UNK |
| Lower Explosion Limit | N/A |
| Upper Explosion Limit | N/A |
| Extinguishing Media | N/A |
| Special Fire Fighting Procedures | IN HIGH TEMP. FIRE >1000F, SCBA FOR PROTECTION AGAINST HYDROGEN CHLORIDE |
| Unusual Fire/Explosion Hazards | N/A |
| Stability | YES |
| Stability Conditions to Avoid | N/A |
| Materials to Avoid | STRONG OXIDIZERS |
| Hazardous Decomposition Products | NONE AT ROOM TEMP.; AT SOLDERING TEMP, HYDROLIC ACID |
| Hazardous Polymerization | NO |
| Polymerization Conditions to Avoid | WILL NOT OCCUR |
| Route of Entry: Skin | YES |
| Route of Entry: Ingestion | YES |
| Route of Entry: Inhalation | YES |
| Health Hazards - Acute and Chronic | INHALE: SOLDERING TEMP.-IRRITATION OF MUCOUS MEMBRANES. MAY CAUSE PERMANENT INJURY, CAN CAUSE PULMONARY EDEMA. INGEST/SKIN: IRRITANT EYE: IRRITANT W/BURNING |
| Symptoms of Overexposure | SEE ABOVE |
| Medical Cond. Aggrevated by Exposure | SKIN DISORDER, RESPIRATORY INSUFFICIENCIES, LUNG DISORDERS |
| Emergency/First Aid Procedures | INHALE: IF SYMPTOMS OF MALAISE APPEAR, MOVE PATIENT INTO FRESH AIR. INGEST: INDUCE VOMITING UNTIL VOMIT IS CLEAR. SKIN: WASH IMMED. W/WATER & SOAP. APPLY HAND LOTION. EYE: FLUSH W/LG AMOUNT OF WATER FOR 10-15 MIN. AND APPLY EYE SOLN |
| Steps if Material Released/Spilled | SMALL: NEUTRALIZE, ADD ABSORBANT ADN PUT IN CONTAINER. LARGE: FLUSH W/WATER INTO INDUSTRIAL SEWAGE SYSTEM. CAN ALSO BE NEUTRALIZED PRIOR TO FLUSHING |
| Waste Disposal Method | DISPOSE OF I/A/W ALL FEDERAL, STATE AND LOCAL LAW |
| Handling and Storage Precautions | STORE IN DRY, COOL AREA. COMMENSURABLE W/GOOD PRACTICE |
| Respiratory Protection | AT ELEVATED TEMP USE RESPIRATION APPROVED BY NIOSH/MSHA |
| Protective Gloves | SOLVENT RESISTANT |
| Eye Protection | GOGGLES |
| Other Protective Equipment | EYE WASH AND CLOTHING TO COVER SKIN. SOLVENT RESISTANT APRON |
| Supplemental Health/Safety Data | IT IS ADVISABLE TO NOT ALLOW PREGNANT WOMEN IN SOLDERING AREA |
| Disposal Code | O |
| Protect Eye | YES |
| Protect Skin | YES |
| Protect Respiratory | YES |
| Chronic Indicator | YES |
| Contact Code | SLIGHT |
| Fire Code | UNKNOWN |
| Health Code | UNKNOWN |
| React Code | UNKNOWN |
| Specific Hazard and Precaution | MAY CAUSE PERMANENT INJURY TO MUCOUS MEMBRANES, CAN CAUSE PULMONARY EDEMA, WILL IRRITATE SKIN, EYES AND GASTROINTESTINAL TRACT |
| Container Quantity | 1 |
| Unit of Measure | QT |
| Ingredient # | 01 |
| Ingredient Name | 1-AMINOGINTARIC ACID HYDROCHLORIC |
| CAS Number | 138158 |
| Proprietary | NO |
| Percent | 0 |
| OSHA PEL | N/E |
| ACGIH TLV | N/E |
| Ingredient # | 02 |
| Ingredient Name | CARBAMIDE |
| CAS Number | 57136 |
| Proprietary | NO |
| Percent | 0 |
| OSHA PEL | N/E |
| ACGIH TLV | N/E |
| Ingredient # | 03 |
| Ingredient Name | WATER |
| CAS Number | 7732185 |
| Proprietary | NO |
| Percent | 0 |
| OSHA PEL | N/E |
| ACGIH TLV | N/E |