| Home | 29 CFR: 1910 or 1926 | 40 CFR | 49 CFR | Federal Register | MSDS Search | Purchase CFR e-Books |
Any used pipe installed in a pipeline system must comply with § 195.112 (a) and (b) and the following:
(a) The pipe must be of a known specification and the seam joint factor must be determined in accordance with § 195.106(e). If the specified minimum yield strength or the wall thickness is not known, it is determined in accordance with § 195.106 (b) or (c) as appropriate.
(b) There may not be any:
(1) Buckles;
(2) Cracks, grooves, gouges, dents, or other surface defects that exceed the maximum depth of such a defect permitted by the specification to which the pipe was manufactured; or
(3) Corroded areas where the remaining wall thickness is less than the minimum thickness required by the tolerances in the specification to which the pipe was manufactured.
[Amdt. 195-22, 46 FR 38360, July 27, 1981; 47 FR 32721, July 29, 1982]