§ 75.32 Determination of monitor data availability for standard missing data procedures.
(a) Following initial certification (i.e., the date and time at which quality assured data begins to be recorded by the CEMS), upon completion of: the first 720 quality-assured monitor operating hours of an SO2 pollutant concentration monitor, or a CO2 pollutant concentration monitor (or O2 monitor used to determine CO2 concentration), or an O2 or CO2 diluent monitor used to calculate heat input or a moisture monitoring system; or the first 2,160 quality-assured monitor operating hours of a flow monitor or a NOX-diluent monitoring system or a NOX concentration monitoring system, the owner or operator shall calculate and record, by means of the automated data acquisition and handling system, the percent monitor data availability for the SO2 pollutant concentration monitor, the CO2 pollutant concentration monitor, the O2 or CO2 diluent monitor used to calculate heat input, the moisture monitoring system, the flow monitor, the NOX-diluent monitoring system and the NOX concentration monitoring system as follows:
(1) Prior to completion of 8,760 unit operating hours following initial certification, the owner or operator shall, for the purpose of applying the standard missing data procedures of § 75.33, use equation 8 to calculate, hourly, percent monitor data availability.